Użycie z niskie powiększenie mikroskop

Aug 31, 2023

 

(1) Lustro pobranie i umieszczenie: Mikroskop jest zwykle przechowywane w a szafka lub pudełko, i kiedy używane, to jest wzięte wyjęte z szafki. Trzymaj lustro ramię ciasno z twoje prawa ręka, i przytrzymaj lustro ba podstawa z twoja lewa ręka. Umieść mikroskop na eksperymentalna stół w przód twój lewy ramię, z z tył koniec lustro ba podstawa 1-2} cale oddalenie oddalenie from the table edge, making it easy to operate while sitting


(2) Aiming: Use your thumb and middle finger to move the rotator (avoid holding the objective lens), so that the low-power lens is aligned with the through-hole of the lens (when you hear a knocking sound during rotation, it indicates that the optical axis of the objective lens is aligned with the center of the lens tube). Open the aperture, raise the concentrator, and turn the reflector towards the light source. Observe with your left eye on the eyepiece (right eye open), while adjusting the direction of the reflector until the light in the field of view is evenly bright


(3) Miejsce a szkło slajd próbka: Wziąć a szkło slajd próbka and miejsce to na lustro stło, robienie pewność że strona z przykrywa szkło jest twarzą do góry. Do not place it upside down. Use a pusher spring clamp to clamp it, and then rotate the pusher screw to adjust the observed area to the center of the light hole


(4) Regulacja ogniskowa długość: Obróć the coarse adjuster przeciwnie do ruchu wskazówek zegara with t left hand to slowly raise the lens to a distance of about 5 millimeters from the objective lens to the specimen. It should be noted that when raising the lens, do not note note obserwe from the eyepiec. Be sure to watch the lens rise from the right side to avoid damage to the lens or specimen. Wtedy, otwórz oba oczy at the same time, observe with your left eye on the eye the eye the covere, and slowly rotate the coarse adjuster prawos with your left hand to slowly lower the lens, Until a clear object appears in the field of vision


If the object is not in the center of the field of view, the slide pusher can be adjusted to adjust it to the center (note that the direction of moving the slide is opposite to the direction of moving the object in the field of view). If the brightness in the field of view is not suitable, it can be adjusted by adjusting the position of the light collector or the size of the opening and closing aperture. If the lens has dropped beyond the working distance (>5.40mm) when adjusting the focal length and no object is seen, it indicates that the operation has failed, and it should be re operated, Never rush and blindly raise the mirror platform

 

2 Electronic Microscope

 

 